Our company produces various types and specifications of steel core aluminum stranded wire, aluminum-clad steel stranded wire, steel stranded wire, expanded wire, aluminum-clad steel core aluminum stranded wire, heat-resistant aluminum alloy overhead wire, high and low voltage overhead insulated cable, cluster wire, power cable, etc. The products are widely used in the power construction and rural power grid transformation of the State Grid, Henan, Shandong, Jiangsu, Jiangxi, Shanxi, Shaanxi, Inner Mongolia, Xinjiang and other provinces, sold throughout the country, well received.
Product Details
Table 16 Structural Dimensions and Technical Parameters of BS3 One-Two-Core Conductor with Two-Core Conductor
(BS3-JKV,BS3-JKLV,BS3-JKY,BS3-JKLY,BS3-JKYJ,BS3-JKLYJ 0.6kV)
Number of cores × Nominal section mm² |
least in conductor Single line root number |
Outer diameter of conductor mm (reference value) |
Insulation thickness mm |
Size of connecting bar Thickness x length (approximate) |
Conductor resistance at 20 ℃ not greater Ω/km |
At rated operating temperature Minimum insulation resistance MΩ·km |
Comprehensive breaking force N |
||||
Compact Round | |||||||||||
COPPER CORE | Aluminum core | COPPER CORE | Aluminum core | 70℃ | 90℃ | COPPER CORE | Aluminum core | ||||
2 x 4 | 1 | 1 | 2.26 | 0.9 | 0.6 × 2.0 | 4.610 | 7.410 | 0.0100 | 1.00 | 1840 | 1100 |
2 x 6 | 1 | 1 | 2.76 | 0.9 | 0.6 × 2.0 | 3.080 | 4.910 | 0.0087 | 0.87 | 2760 | 1651 |
2 × 10 | 6 | 1 | Copper 3.80 Aluminum 3.56 |
1.0 | 0.7 × 2.5 | 1.830 | 3.080 | 0.0067 | 0.67 | 4600 | 2752 |
2 × 16 | 6 | 6 | 4.80 | 1.2 | 0.9 × 3.0 | 1.150 | 1.910 | 0.0065 | 0.65 | 7360 | 4403 |
2 × 25 | 6 | 6 | 6.00 | 1.2 | 1.0 × 3.0 | 0.727 | 1.200 | 0.0054 | 0.54 | 11500 | 6880 |
2 × 35 | 6 | 6 | 7.00 | 1.4 | 1.0 × 3.0 | 0.524 | 0.868 | 0.0054 | 0.54 | 16100 | 9632 |
2 × 50 | 6 | 6 | 8.30 | 1.4 | 1.0 × 3.0 | 0.387 | 0.641 | 0.0046 | 0.46 | 23000 | 13760 |
2 × 70 | 12 | 12 | 10.00 | 1.4 | 1.0 × 3.0 | 0.268 | 0.443 | 0.0040 | 0.40 | 32200 | 19180 |
2 × 95 | 15 | 15 | 11.60 | 1.6 | 1.0 × 3.0 | 0.193 | 0.320 | 0.0039 | 0.39 | 43700 | 26030 |
2 × 120 | 18 | 15 | 13.00 | 1.6 | 1.0 × 3.0 | 0.153 | 0.253 | 0.0035 | 0.35 | 55200 | 32880 |
Table 17.1 Structural Dimensions and Technical Parameters of BS1-Four Core Parallel Cluster Insulated Conductor with Same Section
(BS3-JKV,BS3-JKLV,BS3-JKY,BS3-JKLY,BS3-JKYJ,BS3-JKLYJ 0.6/1kV)
Number of cores × Nominal section mm² |
least in conductor Single line root number |
Outer diameter of conductor mm (reference value) |
Insulation Thickness mm |
Size of connecting bar Thickness x length (approximate) |
Conductor resistance at 20 ℃ not greater Ω/km |
At rated operating temperature Minimum insulation resistance |
Comprehensive breaking force N |
|||||
Compact Round | MΩ·km | |||||||||||
COPPER CORE | Aluminum core | Vertical | Transverse | COPPER CORE | Aluminum core | 70℃ | 90℃ | COPPER CORE | Aluminum core | |||
4 x 10 | 6 | 1 | Copper 3.80 Aluminum 3.56 |
1 | 0.7 × 2.0 | 0.3 × 5.8 | 1.830 | 3.080 | 0.0067 | 0.67 | 9200 | 5480 |
4 × 16 | 6 | 6 | 4.8 | 1.2 | 0.7 × 3.0 | 0.3 × 7.5 | 1.150 | 1.910 | 0.0065 | 0.65 | 14720 | 8806 |
4 x 25 | 6 | 6 | 6.0 | 1.2 | 0.9 × 3.0 | 0.3 × 8.0 | 0.727 | 1.200 | 0.0054 | 0.54 | 23000 | 13760 |
4 × 35 | 6 | 6 | 7.0 | 1.4 | 0.9 × 3.0 | 0.4 × 8.5 | 0.524 | 0.868 | 0.0054 | 0.54 | 32200 | 19264 |
4 x 50 | 6 | 6 | 8.3 | 1.4 | 0.9 × 3.0 | 0.4 × 9.5 | 0.387 | 0.641 | 0.0046 | 0.46 | 46000 | 27520 |
4 × 70 | 12 | 12 | 10.0 | 1.4 | 0.9 × 3.0 | 0.4 × 11.0 | 0.268 | 0.443 | 0.0040 | 0.40 | 64400 | 38360 |
4 × 95 | 15 | 15 | 11.6 | 1.6 | 1.0 × 3.0 | 0.5 × 12.0 | 0.193 | 0.320 | 0.0039 | 0.39 | 87400 | 52060 |
4 × 120 | 18 | 15 | 13.0 | 1.6 | 1.0 × 3.0 | 0.5 × 12.5 | 0.153 | 0.253 | 0.0035 | 0.35 | 110400 | 65760 |
Note: Approximate value refers to the value that should not be verified and checked, but should be fully considered in design and process manufacturing. |
Table 17.2 Structural Dimensions and Technical Parameters of BS1-Four-core Parallel Bundle Insulated Conductor with Different Sections
(BS3-JKV,BS3-JKLV,BS3-JKY,BS3-JKLY,BS3-JKYJ,BS3-JKLYJ 0.6/1kV)
Number of cores × Nominal section mm² |
least in conductor Single line root number |
Outer diameter of conductor mm (reference value) |
Insulation Thickness mm |
Size of connecting bar Thickness x length (approximate) |
Conductor resistance at 20 ℃ is not more Ω/km |
Rated work Temperature at minimum Insulation resistance MΩ·km |
Comprehensive breaking force N |
|||||||||||
Compact Round | COPPER CORE | Aluminum core | Main line core | |||||||||||||||
COPPER CORE | Aluminum core | |||||||||||||||||
phase wire core | Zero line core | phase wire core | Zero line core | phase wire core | Zero line core | phase wire core | Zero line core | Vertical | Transverse | phase wire core | Zero line core | phase wire core | Zero line core | 70℃ | 00°C 00C |
COPPER CORE | Aluminum core | |
3 × 35 1 × 25 |
6 | 6 | 6 | 6 | 7.00 | 6.0 | 1.4 | 1.2 | 0.9 × 3.0 | 0.4 × 8.5 | 0.524 | 0.727 | 0.868 | 1.200 | 0.0054 | 0.54 | 29900 | 17810 |
3 x 50 1 × 35 |
6 | 6 | 6 | 6 | 8.30 | 7.0 | 1.4 | 1.4 | 0.9 × 3.0 | 0.4 × 9.5 | 0.387 | 0.524 | 0.641 | 0.868 | 0.0046 | 0.46 | 42550 | 25345 |
3 × 70 1 × 50 |
12 | 12 | 12 | 6 | 10.00 | 8.3 | 1.4 | 1.4 | 0.9 × 3.0 | 0.4 × 11.0 | 0.268 | 0.387 | 0.443 | 0.641 | 0.0040 | 0.40 | 59800 | 35620 |
3 × 95 1 × 70 |
15 | 15 | 15 | 12 | 11.60 | 10.0 | 1.6 | 1.4 | 1.0 × 3.0 | 0.5 × 12.0 | 0.193 | 0.268 | 0.320 | 0.443 | 0.0039 | 0.39 | 81650 | 58635 |
3 × 120 1 × 95 |
18 | 15 | 15 | 15 | 13.00 | 11.6 | 1.6 | 1.6 | 1.0 × 3.0 | 0.5 × 12.5 | 0.153 | 0.193 | 0.253 | 0.320 | 0.0035 | 0.35 | 10465 | 62335 |